MAINTENANCE OF A BALL TRAP

MAINTENANCE OF A SYNTHETIC GRANULATE BULK TRAP

BALL TRAP   -   INTERIOR BALL PITS   -   OTHER BALL TRAPS   -   RUBBER SLATS   -   TRADING

A) Weekly (The maintenance can be done by the person (s) responsible for the maintenance of the shooting stand)

- Maintenance of the thickness of the aggregates part by a total of aggregates. The depressions of the hillock should not exceed 20 cm.

- Visual verification of the wear of the rubber protection mats and patch repair if necessary.

 

B) All 100,000 shots per line of fire: This maintenance must be performed by a specialized company or personnel with specialized training

* Area to be treated:

* Width: Full width of the stand

* Height: Up to +3 m level

* Depth: Until Geotextile

Methodology: Purge all the aggregates and sort by aspiration the firing waste.

Aggregates in good condition can be reinjected into the mound.

Verification of the geotextile and the condition of the earth core.

Changed carpets and / or firing windows.

Evacuation of firing waste in controlled landfill.

 

C) Every 500,000 shots per line of fire:

This maintenance must be carried out by a specialized company Area to be treated :

The entire shooting butt

Purge all the granulate

Purge of the earth core

Checking the shield at the bottom of the wall

Changing rubber mats

Evacuation of waste in specialized landfill.

 

After removing the firing windows, the aggregates are transformed into powder. This powder must be broken and removed with a special machine, taking care to purge warheads and lead residues. This technique is tedious and we recommend that it should be carried out by a specialized team. The waste is transported in sealed containers and transported to a special waste treatment plant.

Once the residues are removed simply replace with new aggregates, replace the firing windows with new ones fixed on the existing velcro strips.

 

CODEX-TIR can perform 100,000 firing and 500,000 firing line firing (Article B and C) of the firing butt and follow-up all over France and abroad with the participation and collaboration of these partners VMS and GTS Electronica

 

MAINTENANCE OF A BALL TRAP IN GRANULATE RUBBER

 

Regarding the rubber PAB the methodology is the same, only differs the metallic PAB The maintenance of these must be done for a PAB 3 times a year

FIRST INTERVENTION  Clean-up of the PAB by removing the warheads housed in the receptacles provided for this purpose, and around the PAB Aspiration of firing powders using a vacuum cleaner at the ATTEX Standards Floor washing

SECOND INTERVENTION Same operation as the previous one

THIRD INTERVENTION Same as the second Suction of powders from the wall and ceiling Floor washing Residues of lead, powder, dust and washing water must be evacuated to a specialized sorting center.